Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Protein Sci ; 33(5): e4992, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38647406

RESUMEN

Advances in machine learning have enabled sufficiently accurate predictions of protein structure to be used in macromolecular structure determination with crystallography and cryo-electron microscopy data. The Phenix software suite has AlphaFold predictions integrated into an automated pipeline that can start with an amino acid sequence and data, and automatically perform model-building and refinement to return a protein model fitted into the data. Due to the steep technical requirements of running AlphaFold efficiently, we have implemented a Phenix-AlphaFold webservice that enables all Phenix users to run AlphaFold predictions remotely from the Phenix GUI starting with the official 1.21 release. This webservice will be improved based on how it is used by the research community and the future research directions for Phenix.


Asunto(s)
Modelos Moleculares , Proteínas , Programas Informáticos , Proteínas/química , Conformación Proteica , Pliegue de Proteína , Aprendizaje Automático , Internet
2.
Am J Vet Res ; 85(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38320399

RESUMEN

OBJECTIVE: To define reference intervals (RIs) for arterial blood gas (aBG) measurements in healthy, nonsedated, dolichocephalic, and mesocephalic (nonbrachycephalic) dogs at approximately 1,535 m above sea level and compare these findings with healthy, nonsedated, brachycephalic dogs living at the same altitude. ANIMALS: 120 adult nonbrachycephalic dogs and 20 adult brachycephalic dogs. METHODS: Cases were prospectively enrolled from October 2021 to June 2022. Dogs were enrolled from the community or after presentation for wellness examinations or minor injuries including lacerations, nail injuries, and lameness. Physical examinations and systolic blood pressure (sBP) measurements were obtained before blood sample collection. Arterial blood was collected from the dorsal pedal artery or femoral artery. After data collection, brachycephalic dogs underwent pre- and postexercise tolerance assessments. RESULTS: The mean and RI values for arterial pH (7.442; 7.375 to 7.515), partial pressure of oxygen in arterial blood (Pao2; 78.3; 59.2 to 92.7 mm Hg), partial pressure of carbon dioxide in arterial blood (Paco2; 28.0; 21.5 to 34.4 mm Hg), saturation of arterial oxygen (Sao2; 98.4; 84.3% to 101.4%), HCO3 (18.9; 14.9 to 22.4 mmol/L), concentration of total hemoglobin (ctHb; 17.5; 13.4 to 21.1 g/dL), and sBP (133; 94 to 180 mm Hg) were established for healthy nonbrachycephalic dogs at 1,535-m altitude. All aBG measurements were statistically and clinically different from those previously reported for dogs at sea level. Brachycephalic dogs had significantly lower Pao2 and Sao2 (P = .0150 and P = .0237, respectively) and significantly higher ctHb (P = .0396) compared to nonbrachycephalic dogs acclimatized to the same altitude; the nonbrachycephalic RIs were not transferable to the brachycephalic dogs for Pao2. CLINICAL RELEVANCE: This study represents the first collation of aBG measurements for healthy nonbrachycephalic dogs acclimatized to an altitude of 1,535 m. Additionally, this study identified differences in arterial oxygenation measurements between brachycephalic and nonbrachycephalic dogs. RIs in brachycephalic dogs need to be established.


Asunto(s)
Craneosinostosis , Enfermedades de los Perros , Perros , Animales , Altitud , Análisis de los Gases de la Sangre/veterinaria , Craneosinostosis/veterinaria , Oxígeno , Dióxido de Carbono , Enfermedades de los Perros/diagnóstico
3.
Nat Methods ; 21(1): 110-116, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38036854

RESUMEN

Artificial intelligence-based protein structure prediction methods such as AlphaFold have revolutionized structural biology. The accuracies of these predictions vary, however, and they do not take into account ligands, covalent modifications or other environmental factors. Here, we evaluate how well AlphaFold predictions can be expected to describe the structure of a protein by comparing predictions directly with experimental crystallographic maps. In many cases, AlphaFold predictions matched experimental maps remarkably closely. In other cases, even very high-confidence predictions differed from experimental maps on a global scale through distortion and domain orientation, and on a local scale in backbone and side-chain conformation. We suggest considering AlphaFold predictions as exceptionally useful hypotheses. We further suggest that it is important to consider the confidence in prediction when interpreting AlphaFold predictions and to carry out experimental structure determination to verify structural details, particularly those that involve interactions not included in the prediction.


Asunto(s)
Inteligencia Artificial , Procesos Mentales , Cristalografía , Conformación Proteica
4.
Acta Crystallogr D Struct Biol ; 79(Pt 12): 1079-1093, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37942718

RESUMEN

Neutron diffraction is one of the three crystallographic techniques (X-ray, neutron and electron diffraction) used to determine the atomic structures of molecules. Its particular strengths derive from the fact that H (and D) atoms are strong neutron scatterers, meaning that their positions, and thus protonation states, can be derived from crystallographic maps. However, because of technical limitations and experimental obstacles, the quality of neutron diffraction data is typically much poorer (completeness, resolution and signal to noise) than that of X-ray diffraction data for the same sample. Further, refinement is more complex as it usually requires additional parameters to describe the H (and D) atoms. The increase in the number of parameters may be mitigated by using the `riding hydrogen' refinement strategy, in which the positions of H atoms without a rotational degree of freedom are inferred from their neighboring heavy atoms. However, this does not address the issues related to poor data quality. Therefore, neutron structure determination often relies on the presence of an X-ray data set for joint X-ray and neutron (XN) refinement. In this approach, the X-ray data serve to compensate for the deficiencies of the neutron diffraction data by refining one model simultaneously against the X-ray and neutron data sets. To be applicable, it is assumed that both data sets are highly isomorphous, and preferably collected from the same crystals and at the same temperature. However, the approach has a number of limitations that are discussed in this work by comparing four separately re-refined neutron models. To address the limitations, a new method for joint XN refinement is introduced that optimizes two different models against the different data sets. This approach is tested using neutron models and data deposited in the Protein Data Bank. The efficacy of refining models with H atoms as riding or as individual atoms is also investigated.


Asunto(s)
Difracción de Neutrones , Neutrones , Rayos X , Difracción de Rayos X , Cristalografía , Difracción de Neutrones/métodos , Cristalografía por Rayos X
5.
Methods Enzymol ; 688: 195-222, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37748827

RESUMEN

This chapter discusses the use of diffraction simulators to improve experimental outcomes in macromolecular crystallography, in particular for future experiments aimed at diffuse scattering. Consequential decisions for upcoming data collection include the selection of either a synchrotron or free electron laser X-ray source, rotation geometry or serial crystallography, and fiber-coupled area detector technology vs. pixel-array detectors. The hope is that simulators will provide insights to make these choices with greater confidence. Simulation software, especially those packages focused on physics-based calculation of the diffraction, can help to predict the location, size, shape, and profile of Bragg spots and diffuse patterns in terms of an underlying physical model, including assumptions about the crystal's mosaic structure, and therefore can point to potential issues with data analysis in the early planning stages. Also, once the data are collected, simulation may offer a pathway to improve the measurement of diffraction, especially with weak data, and might help to treat problematic cases such as overlapping patterns.


Asunto(s)
Análisis de Datos , Programas Informáticos , Simulación por Computador , Cristalografía , Sustancias Macromoleculares
6.
Acta Crystallogr D Struct Biol ; 79(Pt 3): 234-244, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36876433

RESUMEN

Experimental structure determination can be accelerated with artificial intelligence (AI)-based structure-prediction methods such as AlphaFold. Here, an automatic procedure requiring only sequence information and crystallographic data is presented that uses AlphaFold predictions to produce an electron-density map and a structural model. Iterating through cycles of structure prediction is a key element of this procedure: a predicted model rebuilt in one cycle is used as a template for prediction in the next cycle. This procedure was applied to X-ray data for 215 structures released by the Protein Data Bank in a recent six-month period. In 87% of cases our procedure yielded a model with at least 50% of Cα atoms matching those in the deposited models within 2 Å. Predictions from the iterative template-guided prediction procedure were more accurate than those obtained without templates. It is concluded that AlphaFold predictions obtained based on sequence information alone are usually accurate enough to solve the crystallographic phase problem with molecular replacement, and a general strategy for macromolecular structure determination that includes AI-based prediction both as a starting point and as a method of model optimization is suggested.


Asunto(s)
Inteligencia Artificial , Cristalografía , Bases de Datos de Proteínas , Modelos Estructurales
7.
Biochim Biophys Acta Biomembr ; 1865(4): 184133, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36738875

RESUMEN

Cryo-EM observation of biological samples enables visualization of sample heterogeneity, in the form of discrete states that are separable, or continuous heterogeneity as a result of local protein motion before flash freezing. Variability analysis of this continuous heterogeneity describes the variance between a particle stack and a volume, and results in a map series describing the various steps undertaken by the sample in the particle stack. While this observation is absolutely stunning, it is very hard to pinpoint structural details to elements of the maps. In order to bridge the gap between observation and explanation, we designed a tool that refines an ensemble of structures into all the maps from variability analysis. Using this bundle of structures, it is easy to spot variable parts of the structure, as well as the parts that are not moving. Comparison with molecular dynamics simulations highlights the fact that the movements follow the same directions, albeit with different amplitudes. Ligand can also be investigated using this method. Variability refinement is available in the Phenix software suite, accessible under the program name phenix.varref.


Asunto(s)
Proteínas , Programas Informáticos , Microscopía por Crioelectrón/métodos , Proteínas/química , Conformación Proteica , Simulación de Dinámica Molecular
8.
Acta Crystallogr D Struct Biol ; 79(Pt 2): 100-110, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36762856

RESUMEN

In macromolecular crystallographic structure refinement, ligands present challenges for the generation of geometric restraints due to their large chemical variability, their possible novel nature and their specific interaction with the binding pocket of the protein. Quantum-mechanical approaches are useful for providing accurate ligand geometries, but can be plagued by the number of minima in flexible molecules. In an effort to avoid these issues, the Quantum Mechanical Restraints (QMR) procedure optimizes the ligand geometry in situ, thus accounting for the influence of the macromolecule on the local energy minima of the ligand. The optimized ligand geometry is used to generate target values for geometric restraints during the crystallographic refinement. As demonstrated using a sample of >2330 ligand instances in >1700 protein-ligand models, QMR restraints generally result in lower deviations from the target stereochemistry compared with conventionally generated restraints. In particular, the QMR approach provides accurate torsion restraints for ligands and other entities.


Asunto(s)
Proteínas , Programas Informáticos , Conformación Proteica , Ligandos , Modelos Moleculares , Cristalografía por Rayos X , Proteínas/química
9.
Acta Crystallogr D Struct Biol ; 78(Pt 11): 1303-1314, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36322415

RESUMEN

AlphaFold has recently become an important tool in providing models for experimental structure determination by X-ray crystallography and cryo-EM. Large parts of the predicted models typically approach the accuracy of experimentally determined structures, although there are frequently local errors and errors in the relative orientations of domains. Importantly, residues in the model of a protein predicted by AlphaFold are tagged with a predicted local distance difference test score, informing users about which regions of the structure are predicted with less confidence. AlphaFold also produces a predicted aligned error matrix indicating its confidence in the relative positions of each pair of residues in the predicted model. The phenix.process_predicted_model tool downweights or removes low-confidence residues and can break a model into confidently predicted domains in preparation for molecular replacement or cryo-EM docking. These confidence metrics are further used in ISOLDE to weight torsion and atom-atom distance restraints, allowing the complete AlphaFold model to be interactively rearranged to match the docked fragments and reducing the need for the rebuilding of connecting regions.


Asunto(s)
Programas Informáticos , Modelos Moleculares , Cristalografía por Rayos X , Conformación Proteica , Microscopía por Crioelectrón
10.
Nat Methods ; 19(11): 1376-1382, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36266465

RESUMEN

Machine-learning prediction algorithms such as AlphaFold and RoseTTAFold can create remarkably accurate protein models, but these models usually have some regions that are predicted with low confidence or poor accuracy. We hypothesized that by implicitly including new experimental information such as a density map, a greater portion of a model could be predicted accurately, and that this might synergistically improve parts of the model that were not fully addressed by either machine learning or experiment alone. An iterative procedure was developed in which AlphaFold models are automatically rebuilt on the basis of experimental density maps and the rebuilt models are used as templates in new AlphaFold predictions. We show that including experimental information improves prediction beyond the improvement obtained with simple rebuilding guided by the experimental data. This procedure for AlphaFold modeling with density has been incorporated into an automated procedure for interpretation of crystallographic and electron cryo-microscopy maps.


Asunto(s)
Algoritmos , Proteínas , Modelos Moleculares , Microscopía por Crioelectrón/métodos , Proteínas/química , Aprendizaje Automático , Conformación Proteica
11.
J Struct Biol ; 214(1): 107841, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35149213

RESUMEN

Integrative modeling computes a model based on varied types of input information, be it from experiments or prior models. Often, a type of input information will be best handled by a specific modeling software package. In such a case, we desire to integrate our integrative modeling software package, Integrative Modeling Platform (IMP), with software specialized to the computational demands of the modeling problem at hand. After several attempts, however, we have concluded that even in collaboration with the software's developers, integration is either impractical or impossible. The reasons for the intractability of integration include software incompatibilities, differing modeling logic, the costs of collaboration, and academic incentives. In the integrative modeling software ecosystem, several large modeling packages exist with often redundant tools. We reason, therefore, that the other development groups have similarly concluded that the benefit of integration does not justify the cost. As a result, modelers are often restricted to the set of tools within a single software package. The inability to integrate tools from distinct software negatively impacts the quality of the models and the efficiency of the modeling. As the complexity of modeling problems grows, we seek to galvanize developers and modelers to consider the long-term benefit that software interoperability yields. In this article, we formulate a demonstrative set of software standards for implementing a model search using tools from independent software packages and discuss our efforts to integrate IMP and the crystallography suite Phenix within the Bayesian modeling framework.


Asunto(s)
Ecosistema , Teorema de Bayes , Programas Informáticos
12.
J Chem Phys ; 156(4): 041102, 2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35105059

RESUMEN

Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. This imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 µm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 109-1011 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.

13.
Acta Crystallogr D Struct Biol ; 77(Pt 1): 48-61, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33404525

RESUMEN

The field of electron cryomicroscopy (cryo-EM) has advanced quickly in recent years as the result of numerous technological and methodological developments. This has led to an increase in the number of atomic structures determined using this method. Recently, several tools for the analysis of cryo-EM data and models have been developed within the Phenix software package, such as phenix.real_space_refine for the refinement of atomic models against real-space maps. Also, new validation metrics have been developed for low-resolution cryo-EM models. To understand the quality of deposited cryo-EM structures and how they might be improved, models deposited in the Protein Data Bank that have map resolutions of better than 5 Šwere automatically re-refined using current versions of Phenix tools. The results are available on a publicly accessible web page (https://cci.lbl.gov/ceres). The implementation of a Cryo-EM Re-refinement System (CERES) for the improvement of models deposited in the wwPDB, and the results of the re-refinements, are described. Based on these results, contents are proposed for a `cryo-EM Table 1', which summarizes experimental details and validation metrics in a similar way to `Table 1' in crystallography. The consistent use of robust metrics for the evaluation of cryo-EM models and data should accompany every structure deposition and be reported in scientific publications.


Asunto(s)
Microscopía por Crioelectrón/métodos , Procesamiento de Imagen Asistido por Computador , Modelos Moleculares , Programas Informáticos , Bases de Datos de Proteínas , Sustancias Macromoleculares/química , Conformación Molecular
14.
Acta Crystallogr D Struct Biol ; 75(Pt 10): 861-877, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31588918

RESUMEN

Diffraction (X-ray, neutron and electron) and electron cryo-microscopy are powerful methods to determine three-dimensional macromolecular structures, which are required to understand biological processes and to develop new therapeutics against diseases. The overall structure-solution workflow is similar for these techniques, but nuances exist because the properties of the reduced experimental data are different. Software tools for structure determination should therefore be tailored for each method. Phenix is a comprehensive software package for macromolecular structure determination that handles data from any of these techniques. Tasks performed with Phenix include data-quality assessment, map improvement, model building, the validation/rebuilding/refinement cycle and deposition. Each tool caters to the type of experimental data. The design of Phenix emphasizes the automation of procedures, where possible, to minimize repetitive and time-consuming manual tasks, while default parameters are chosen to encourage best practice. A graphical user interface provides access to many command-line features of Phenix and streamlines the transition between programs, project tracking and re-running of previous tasks.


Asunto(s)
Automatización/métodos , Sustancias Macromoleculares/química , Diseño de Software , Validación de Programas de Computación , Microscopía por Crioelectrón/métodos , Cristalografía por Rayos X/métodos , Modelos Moleculares , Conformación Molecular
15.
J Struct Biol ; 208(1): 1-6, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31279069

RESUMEN

Cryo-electron microscopy (cryo-EM) is becoming a method of choice for describing native conformations of biomolecular complexes at high resolution. The rapid growth of cryo-EM in recent years has created a high demand for automated solutions, both in hardware and software. Flexible fitting of atomic models to three-dimensional (3D) cryo-EM reconstructions by molecular dynamics (MD) simulation is a popular technique but often requires technical expertise in computer simulation. This work introduces cryo_fit, a package for the automatic flexible fitting of atomic models in cryo-EM maps using MD simulation. The package is integrated with the Phenix software suite. The module was designed to automate the multiple steps of MD simulation in a reproducible manner, as well as facilitate refinement and validation through Phenix. Through the use of cryo_fit, scientists with little experience in MD simulation can produce high quality atomic models automatically and better exploit the potential of cryo-EM.


Asunto(s)
Microscopía por Crioelectrón/métodos , Programas Informáticos , Simulación de Dinámica Molecular , Conformación Proteica
17.
Sci Data ; 5: 180201, 2018 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-30277481

RESUMEN

Fluctuation X-ray scattering (FXS) is an emerging experimental technique in which solution scattering data are collected using X-ray exposures below rotational diffusion times, resulting in angularly anisotropic X-ray snapshots that provide several orders of magnitude more information than traditional solution scattering data. Such experiments can be performed using the ultrashort X-ray pulses provided by a free-electron laser source, allowing one to collect a large number of diffraction patterns in a relatively short time. Here, we describe a test data set for FXS, obtained at the Linac Coherent Light Source, consisting of close to 100 000 multi-particle diffraction patterns originating from approximately 50 to 200 Paramecium Bursaria Chlorella virus particles per snapshot. In addition to the raw data, a selection of high-quality pre-processed diffraction patterns and a reference SAXS profile are provided.


Asunto(s)
Phycodnaviridae , Dispersión del Ángulo Pequeño , Difracción de Rayos X
18.
Acta Crystallogr D Struct Biol ; 74(Pt 9): 814-840, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30198894

RESUMEN

Recent advances in the field of electron cryomicroscopy (cryo-EM) have resulted in a rapidly increasing number of atomic models of biomacromolecules that have been solved using this technique and deposited in the Protein Data Bank and the Electron Microscopy Data Bank. Similar to macromolecular crystallography, validation tools for these models and maps are required. While some of these validation tools may be borrowed from crystallography, new methods specifically designed for cryo-EM validation are required. Here, new computational methods and tools implemented in PHENIX are discussed, including d99 to estimate resolution, phenix.auto_sharpen to improve maps and phenix.mtriage to analyze cryo-EM maps. It is suggested that cryo-EM half-maps and masks should be deposited to facilitate the evaluation and validation of cryo-EM-derived atomic models and maps. The application of these tools to deposited cryo-EM atomic models and maps is also presented.


Asunto(s)
Microscopía por Crioelectrón/métodos , Modelos Moleculares , Proteínas/química , Programas Informáticos , Cristalografía por Rayos X , Bases de Datos de Proteínas , Humanos , Conformación Proteica
19.
Acta Crystallogr D Struct Biol ; 74(Pt 6): 531-544, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29872004

RESUMEN

This article describes the implementation of real-space refinement in the phenix.real_space_refine program from the PHENIX suite. The use of a simplified refinement target function enables very fast calculation, which in turn makes it possible to identify optimal data-restraint weights as part of routine refinements with little runtime cost. Refinement of atomic models against low-resolution data benefits from the inclusion of as much additional information as is available. In addition to standard restraints on covalent geometry, phenix.real_space_refine makes use of extra information such as secondary-structure and rotamer-specific restraints, as well as restraints or constraints on internal molecular symmetry. The re-refinement of 385 cryo-EM-derived models available in the Protein Data Bank at resolutions of 6 Šor better shows significant improvement of the models and of the fit of these models to the target maps.


Asunto(s)
Microscopía por Crioelectrón/métodos , Programas Informáticos , Animales , Simulación por Computador , Cristalografía/métodos , Bases de Datos de Proteínas/normas , Humanos , Sustancias Macromoleculares/química , Modelos Moleculares , Canales Catiónicos TRPV/química , Estudios de Validación como Asunto
20.
Protein Sci ; 27(1): 182-194, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28901593

RESUMEN

Often similar structures need to be compared to reveal local differences throughout the entire model or between related copies within the model. Therefore, a program to compare multiple structures and enable correction any differences not supported by the density map was written within the Phenix framework (Adams et al., Acta Cryst 2010; D66:213-221). This program, called Structure Comparison, can also be used for structures with multiple copies of the same protein chain in the asymmetric unit, that is, as a result of non-crystallographic symmetry (NCS). Structure Comparison was designed to interface with Coot(Emsley et al., Acta Cryst 2010; D66:486-501) and PyMOL(DeLano, PyMOL 0.99; 2002) to facilitate comparison of large numbers of related structures. Structure Comparison analyzes collections of protein structures using several metrics, such as the rotamer conformation of equivalent residues, displays the results in tabular form and allows superimposed protein chains and density maps to be quickly inspected and edited (via the tools in Coot) for consistency, completeness and correctness.


Asunto(s)
Modelos Moleculares , Proteínas/química , Interfaz Usuario-Computador , Proteínas/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...